Program 76-1(X-Y) – DK14, DK40i, All RCTUs
Strata DK Programming 5/99 3-157
System & Station
Program 76-1(X-Y) – DK14, DK40i, All RCTUs
Processor Type:
DK14, DK40i, All RCTUs
Program Type:
System
Initialized Default:
Port 1 (Type 1), Ports 2~4 (Type 0)
Program 76-1 Overview
This program assigns each installed WSIU (DK14 only), TSIU (DK40i only) or RSIU/RSIS
(DK424 only) port to a function.
For Program 76-1(X-Y):
X identifies the WSIU, TSIU port number 1~2 or RSIU/RSIS/RMDS port number 1~4.
Y identifies the WSIU, TSIU or RSIU/RSIS/RMDS port function as shown below:
Port types set in this program override RSSU, PIOU, and/or PIOUS function codes (41, 42,
43) set in Program 03. To activate changes made to this program, system power must be turned
off/on or Program 91-2 must be run.
Communication Parameters: SMDI, MIS or SMIS, TTY, IMDU/RMDS, Caller ID, OAI: 7
bits, even parity, 1 stop bit. SMDR: 8 bits, no parity, 1 stop bit.
Port Number Port Type (0~6)
1
2
3
4
Port Type (Y) Function
0 No port equipped. This should be used for any of the four RSIU/RSIS/RMDS ports that are not used.
1
TTY or modem
1
.
TTY RS-232 port (set Program 77-1, LED 14 OFF; DK14, DK40i or DK424).
RMDS modem port (set Program 77-1, LED 14 ON; DK424).
1. If port type code 1 is set, then Program 77-1, LED 14 status determines if the port operates as a system administration/maintenance
modem (LED 14 ON) or an RS-232 administration/maintenance TTY port (LED 14 OFF). For modem operation, an RMDS piggy-
back PCB is required, for RS-232 TTY port, a TSIU, WSIU, RSIU/RSIS/RMDS PCB may be used.
2 SMDR
3 MIS or SMIS (DK424)
4 SMDI
5 Open Architecture Interface (see Program 77-4) (DK424 R3.2)
6 Caller ID output to Caller ID interface box (DK14 only)
2
2. If the DK14 CO lines must pass Caller ID information to the Toshiba telephones, LCD/RPCI-DI, an interface box, TC1041 (MLX-
41), must be connected to one of the WSIU outputs. For more information, see the Caller ID instructions in Chapter 1 – DK14
Installation of the Strata DK Installation and Maintenance Manual.
System power must be cycled or Program 91-2
must be run to transfer Program 76-1 data entries
from temporary memory to working memory.
Y=Port Type (0~6), see table below.
Run Program 91-2
SELECT = 1
X = Port Number (1~4)