Toshiba DK14 Answering Machine User Manual


 
System & Station
Program 34 – Hold Recall Timing
3-94 Strata DK Programming 5/99
Program 34 – Hold Recall Timing
Processor Type:
DK14, DK40i, All RCTUs
Program Type:
Station
Initialized Default:
Assigns a Hold Recall Time of 032 seconds to all ports
Program 34 Overview
Each station can have a different time (from 011 to 160 seconds) from the point of placing a call on
hold to the point of recall. Initialized data assigns a recall time of 032 seconds to all ports.
Processor Port Range Processor Port Range
DK14 000~009 RCTUBA/BB 000~079
DK40i 000~027 RCTUC/D 000~239
RCTUA 000~031 RCTUE/F 000~335
Port Seconds Port Seconds Port Seconds Port Seconds
SELECT = Station Logical Port Number
Enter the port number having its Hold
Recall Time defined.
To add a port range, enter XXX
XXX
(low port
high port).
HUNT TIME = Seconds
Enter the number of seconds the system will
wait (three digits).
Enter 000 for no Hold Recall. Enter 011~160 for
11 to 160 seconds.