Mitel sx-200 Telephone User Manual


 
84
SX-200 ICP MX Technician’s Handbook
Web Interface Connection to the Controller
A web browser can be used to connect to the SX-200 ICP from the LAN
and manage the system using the embedded SX-200 ICP Web Interface.
Before using the SX-200 ICP Web Interface, configure the management
PC as follows:
disable your web browser's pop-up blocker software
install Sun Java plugin version 1.5 or later
With the controller connected to the LAN and the PC connected to the LAN
or Internet:
1. Launch the web browser (IE 6.x or Mozilla Firefox).
2. Enter http://<controller IP or hostname>
For example, http://192.168.1.2
The IP address in the example is the default; use Form 47 to check or
change it.
3. Log in to the SX-200 ICP Web Interface with login name ‘installer’ and
default password ‘1000.’
A CDE session will open.
While the maintenance session is active, do not disconnect the Ethernet
cable or attempt to open another maintenance session with a serial
connection. Doing so will cause an error message stating that CDE is
currently in use.