Mitel sx-200 Telephone User Manual


 
329
Default Database Values
Form 13 - Trunk Circuit Descriptor
[ AMB TRUNK: 1 ] OPTION NAME [SUPERVISION PARAMETER] STATUS
Reverse to Idle NO
Far-end gives answer supervision NO
Inhibit automatic supervision NO
No seize alarm NO
No release alarm NO
Line length LONG
Save Busy-Out Status YES
Impedance COMPLEX
Calling party disconnect timer 1 - 12 minutes 5
Ignore remote disconnect NO
Disconnect timer 100 - 9900 ms ( 100 ms inc ) 500
Supervision direction: incoming trunk calls also NO
Guard timer 0 - 3000 ms ( 100 ms inc ) 800
Class trunk YES
Ring cycle timer 6 - 10 seconds 6
Ignore line reversal during seizure YES
Ringing expected YES
Ringing debounce timer 5 - 12 seconds 6
Seize timer 10 - 60 s ( 10 s inc ) 60
Flash timer 200 - 700 ms ( 100 ms inc ) 300
Flash over trunk NO
Direct access on CO Line Keys: bypass Key System Toll Control NO
[ T1 E&M TRUNK: 7 ] OPTION NAME STATUS
Reverse to Idle NO
Far-end gives answer supervision NO
Inhibit automatic supervision NO
No seize alarm NO
No release alarm NO
Line Length LONG
DTMF NO
Save Busy-Out Status YES
Disconnect timer 1 - 12 minutes 5
Release acknowledge timer 2 - 240 s ( 2 s inc ) 40
Guard timer
200 - 1000 ms ( 100 ms inc )
800
Incoming start type WINK
Debounce timer 20 - 150 ms ( 10 ms inc ) 100
(Page 1 of 2)