Mitel sx-200 Telephone User Manual


 
209
Routine Maintenance
15. Remove the CompactFlash card from the controller when the LED
adjacent to the card slot turns green.
Upgrading by FTP
Before beginning the upgrade, check that the SX-200 ICP is programmed
with the required FTP information in Form 47, Subform 01 (see “Setting up
an FTP Server on a Maintenance PC” on page 75. Also, verify that the
following additional requirements have been satisfied:
existing database is backed up to the PC (for instructions, see
page 203)
Remote Software Download option (System Option 109 in Form 04)
has been purchased and enabled
external CompactFlash card is inserted in the SX-200 ICP (release 1.x
systems only)
The upgrade takes about 3-4 minutes depending on the speed of the FTP
connection. Double the time if installing additional languages for voice mail
prompts.
To upgrade the SX-200 ICP Controller software from an FTP server:
1. Run SX200ICP_SETUP.EXE from the software CD or on-line source.
2. Select Remote Upgrade (FTP) Installation, and then click Next.
3. Select languages for voice mail prompts if applicable. The default is
English and is not selectable.
4. Select the FTP server home directory, then click Next twice to begin
the installation.
5. Click Finish when prompted.
6. Log in to the Maintenance Terminal (direct, secure Telnet, or SX-200
ICP Web Interface) and begin a Maintenance session.
7. Press
SYSTEM
DATABASE
UPGRADE_SW
CONFIRM
8. When prompted, press ENTER to begin the upgrade.
9. If the upgrade failed, consult the Maintenance Logs for the cause.