Mitel sx-200 Telephone User Manual


 
330
SX-200 ICP MX Technician’s Handbook
Form 13 - Audio Configuration Table
Form 13 - Trunk Circuit Descriptor Review
Wink timer 150 - 300 ms ( 50 ms inc ) 200
Outgoing start type WINK
Digit outpulsing ratio 60/40
Outpulse delay timer 100 - 2000 ms ( 100 ms inc ) 800
Flash timer 200 - 700 ms ( 100 ms inc ) 300
Flash type LOOP FSH
Flash over trunk NO
Interdigit timer 300 - 800 ms ( 100 ms inc ) 800
Wait for delay timer 300 - 5000 ms ( 100 ms inc ) 5000
Remote end is a satellite NO
Remote end is a satellite with OPS lines NO
Direct access on CO Line Keys: bypass Key System Toll Control NO
Release Link Trunk NO
QSIG Supplementary Services YES
Present Node ID over IP Trunking NO
TRK BAY SLT CCT LENGTH IMPEDANCE TEL NO MWT COMMENTS
1 AUTO AUTO
2 AUTO AUTO
3 AUTO AUTO
4 AUTO AUTO
5 AUTO AUTO
6 AUTO AUTO
[ AMB TRUNK: 1] TRK NUM BAY SLT CCT COMMENTS
11137
21138
31139
411310
511311
611312
[ T1 E&M TRUNK: 7 ] OPTION NAME STATUS
(Page 2 of 2)