Mitel sx-200 Telephone User Manual


 
160
SX-200 ICP MX Technician’s Handbook
Feature Limitations
Table 25: SX-200 ICP Feature Limitations
Feature Limitation
Maximum number of simultaneous calls 248
Maximum number of Call Park keys 24
Maximum number of Mailbox keys 748
Maximum number of speech paths or channels used
by any call
2
Maximum number of simultaneous consultations 5
Maximum number of System Park Orbits 25
Maximum number of Specific Park Orbits 25
Maximum number of Voice mail Ports 16
Maximum number of Voice mail Boxes 748
Maximum number of simultaneous add-on (3-way)
calls
DSP configuration
dependent
(see page 12)
Maximum number of simultaneous station-controlled
conference calls
DSP configuration
dependent
(see page 12)
Maximum number of parties in conference at one time 5
Maximum number of calls that can simultaneously be
camped on to a station, trunk group, or hunt group
247
Maximum number of simultaneous callbacks that can
be enabled
100
Maximum number of simultaneous call forwards that
can be enabled
650
Maximum number of simultaneous “Dial 0” calls 48
Maximum number of ONS telephones ringing
simultaneously per bay
32
Maximum number of messages queued in the system 750
(Page 1 of 4)