4. Form 13, Options Subform
- Set the Debounce Timer to 100 milliseconds.
- Set the DTMF option to NO.
- Set the Incoming Start Type to WINK.
- Set the Outgoing Start Type to WINK.
5. Form 15, Dial-In Trunks
PRI trunks are Dial-In Trunks and are not normally used in a
Non-Dial-in configuration.
Search for the correct Bay/Slot/Circuit and enter the following for
each trunk:
- COS number – see previous requirements
- COR number (if required)
- Tenant number – unless site has tenanting set to 1
- N – number of incoming DID digits – usually 4
- M – number of digits to absorb – usually 0
- X – digits to be inserted (up to 2 digits) or Feature Access Code
67 (Digit Translation Table Access) programmed on Form 02
- CDN – Circuit Descriptor Number
- Trunk Number – Enter a trunk number (1-200)
6. Form 16, Trunk Groups
- Locate an empty Trunk Group and add the PRI trunks (trunk
numbers programmed in Form 15) to the Trunk Group. (Program
them in reverse order to prevent contention with incoming calls
from the CO.)
- Add a name to the Trunk Group for future reference.
- Set Group Type to Terminal (recommended) or Circular.
- Enable SMDR (outgoing only) if required.