Mitel sx-200 Telephone User Manual


 
178
SX-200 ICP MX Technician’s Handbook
Programming the controller IP address and DHCP
settings
The IP address of the SX-200 ICP and its DHCP settings are set at the
factory. Use the following procedure if you need to change them.
To change the controller’s IP address and DHCP settings:
1. Establish a serial connection to the Maintenance port on the
SX-200 ICP Controller (see page 82 for instructions).
2. Log in to the CDE application.
3. In Form 47 (IP Networking), Subform 01 (SYSTEM IP)
- Enter values for IP ADDRESS, IP NETMASK, IP GATEWAY, and
other settings as required.
4. Press ENTER.
5. In Subform 02 (DHCP SERVER)
- Enter the required values. See the SX-200 ICP Technical
Documentation for information on values to use.
- To disable the controller’s DHCP server, press the DISABLE
softkey; press ENABLE to re-enable it.
6. Press ENTER.
7. Reset the system (see page 197 for instructions).
Configuring a Windows 2000 DHCP server
You can modify a Windows 2000 DHCP server to support IP Phones. A
DHCP server must be configured to support the IP Phones for each
subnet. The following items must be configured:
TFTP Server IP address (system IP address of the SX-200 ICP)
IP address of the RTC card
Mitel tag “MITEL IP PHONE”
To modify a Windows 2000 DHCP Server:
1. On the Start menu, point to Programs, then Administrative Tools,
and click DHCP.
2. Highlight the Server name and point to Action, then click Set
Predefined Options.