Mitel sx-200 Telephone User Manual


 
123
Basic Programming
IMAT provides a confirmation of the connection (for example
“Database received”).
10. Press Okay.
11. In the File menu, select Load -> SW Versions -> Sources -> PRI Card
/Universal NSU. This loads the IMAT with the Software version from
the NSU.
12. Press Load.
IMAT provides a confirmation of the connection (for example
“Software Version received”).
13. Press Okay.
14. Verify that the SW Version of the NSU matches the SW version listed
in the FCI delivered with the latest SX-200 ICP load:
- In the Maintenance menu, select Software versions. Verify the
package version that is listed against the FCI.
- If the package version and the FCI don't match, select SW Upgrade
From IMAT (the NSU load is on the CD).
- After the Upgrade is completed, select Remote Site Reset.
15. Program the NSU Config for the links provided by your PRI provider:
- In the Config menu, select Site Options.
- Confirm the System Type: Universal NSU.
- Confirm the Connected Platform: SX200 EL/ML/ICP.
- If the following options are required, enable them: Qsig, Network
Side Interface.
- In the Config menu, select PRI Link Characteristics.
- Verify BOTH links for Protocol type: DMS250, DMS100, 4ESS,
NI2, QSIG.
- Verify BOTH links for Physical type: T1/CSU or T1/DSX1.
- Verify BOTH links for Characteristics: line coding, line length,
framing, invert data, invert D channel.
- To get a view all of your settings, from the Config menu select View
Database.