Mitel sx-200 Telephone User Manual


 
118
SX-200 ICP MX Technician’s Handbook
To install IMAT on the PC:
1. Close all the applications running on the PC.
2. Insert the SX-200 ICP software CD-ROM in the CD drive.
3. Open the Tools folder, then the Disk 1 folder.
4. Double-click the Setup.exe file. The installation program starts. Follow
the prompts to install IMAT.
Programming IP Settings
Collect the following information:
The Static IP Address that will be programmed on the NSU. Choose
an IP Address that will not conflict with the IP Phone range, which
starts at the default 192.168.1.20 and continues to 192.168.1.250. For
example, you might choose 192.168.1.15 as the static IP address.
The gateway address (if there is a gateway on your network)
The subnet mask (the default setting is 255.255.255.0 which is
represented in hexadecimal as ffffff00)
To program a static IP address on the NSU:
1. Ensure the NSU is disconnected from the SX-200 ICP Controller and
that no power is applied to the NSU. Re-apply power only after
completing CDE and IMAT programming.
2. If you have not already done so, connect a serial cable from a com port
on your PC to the Maintenance port on the NSU.
3. Launch a Hyperterminal session on the PC (38400, 8, N, 1, no flow
control).
4. Apply power to the NSU by connecting the power cord.
Messages are displayed on the PC while the NSU is booting up.
5. When the PC displays “Press any key to stop this autoboot”, press any
key on the PC keyboard. If you do not stop the autoboot on time,
remove the power cord from the NSU and repeat this step
The PC displays “[MC269AA Boot]”
6. Type ‘c’ on the PC keyboard.
The PC displays “boot device”.
7. Press the Enter key until “net on ethernet” is displayed.