Mitel sx-200 Telephone User Manual


 
106
SX-200 ICP MX Technician’s Handbook
IP Printer Port
Data for the functions listed below can be output through an IP socket in
the controller to a telnet-enabled application for printing.
The default database sends SMDR and CDE Data Print output to IP socket
61328. If you are using a different database, follow the procedure below to
program a printer port.
1. Form 11, Data Descriptor
- Define a circuit descriptor to match the characteristics of the device
type. The default circuit descriptor number 1 works for most
applications.
2. Form 12, Data Assignment
- Program a SOCKET type data device to an available PLID in the
following range:
PLID Port PLID Port
1/13/20 61320 1/13/25 61325
1/13/21 61321 1/13/26 61326
1/13/22 61322 1/13/27 61327
1/13/23 61323 1/13/28 61328
1/13/24 61324
- Assign a Tenant, Extension number, COS, COR, and circuit
descriptor number.
3. Form 34, Directed I/O
- Define the printout type to output.
SMDR ACD Real Time Events
CDE Data Print ACD Agent Summary
Maintenance Logs ACD Group Summary
Traffic Measurement Hotel/Motel Audit
IP Traffic Measurement Hotel/Motel Wakeup