Mitel sx-200 Telephone User Manual


 
110
SX-200 ICP MX Technician’s Handbook
If you chose to receive warnings each time a device is deleted, the
system displays “deleting all keys, ...“ for each device in the range.
6. To proceed, press CONFIRM. Press CANCEL to abort the deletion of
the specific device and continue with the next device.
To abort the deletion of a range of devices, press ABORT. Any devices
that were deleted prior to pressing the ABORT key will remain deleted.
Programming a Single Line Voice Station
The default database for a basic system has programming for two
ONS/CLASS circuits. The Analog Option Board adds two more. If you are
starting with a blank database, follow the steps below to program a single
line voice station:
1. Form 01, System Configuration
- Program an ONS or OPS line card.
- Program a Digital Line card or DNIC module for SUPERSET 401+,
and SUPERSET 4001 sets.
2. Form 09, Desktop Device Assignments
- Assign an extension number, COS, COR, and name (optional) for
each bay/slot/circuit (set type remains STATION).
3. Form 30, Device Interconnection Table (optional)
- Set the required interconnect restrictions (for example, to restrict
connections between specific device types).
4. Form 05, Tenant Interconnection Table (optional)
- Set the required interconnect restrictions (for example, to restrict
connections between specific tenants).
5. Form 19, Call Rerouting Table (optional)
- Program how to handle the caller’s call violations.
- Each tenant requires its own Call Rerouting Table.
6. Form 03, COS Define (optional)
- Create a unique class of service (COS) if required.
7. Form 20, ARS: COR Group Definition
- Create a COR group that includes the COR number which you will
assign to the station.