Mitel sx-200 Telephone User Manual


 
114
SX-200 ICP MX Technician’s Handbook
4. Form 04, System Options/System Timers
- Assign values to the first two options in table below and enable the
others as required:
5. Form 13, Trunk Circuit Descriptor
- Assign a T1 trunk circuit descriptor. To receive CLID or DDI digits,
the PRI trunk must be a non-DISA trunk that is programmed with a
T1 E&M trunk circuit descriptor. The Debounce timer must be set
to 100 milliseconds and the Incoming Start type and Outgoing Start
type must be set to WINK.
6. Form 13, Options Subform
- Set the DTMF option to NO.
- Set the QSIG Supplementary Services to “Yes” if you want to insert
the calling name ID when the trunks are programmed for QSIG or
connected to a DMS100.
Table 16: NSU MOSS Options
System Options Setting Notes
Option 48 – Limited Wait for Dial Tone 1-15 secs Set to 1 sec.
Default = 5 sec.
Option 96 – Number of Links 2 Purchase 1 for each link used.
Default = 0
Option 86 - QSIG Optional Enabling Option 86 allows the
called party to see the name of the
caller on their telephone display.
The option is not required if
connected to a DMS100 Central
Office.
Option 91 – NFAS Optional If Option 91 is to be disabled,
Option 92 must be disabled first.
Not required if using a single link
PRI.
Option 92 – D-Channel Backup Optional If Option 92 is to be enabled, Option
91 must already be enabled.
Not required if using a single link
PRI
Option 94 – Min/Max Optional If Option 94 is to be disabled,
Option 95 must be disabled first.
Option 95 – Auto Min/Max Optional If Option 95 is to be enabled, Option
94 must already be enabled.