Mitel sx-200 Telephone User Manual


 
104
SX-200 ICP MX Technician’s Handbook
Programming an Attendant Console
Except for LDN assignments, the programming for a
SUPERCONSOLE 1000 is provided already completed in the default
database (see page 316 for the defaults). If you are starting with a blank
database default, follow the steps below to program the console:
1. Form 01, System Configuration
- Program one of the two DNIC circuits.
2. Form 07, Console Assignment
- Assign an extension number, COS, COR, and Tenant for each
console bay/slot/circuit entry.
3. Form 08, Console LDN Assignment
- Assign a directory number and label to each required console
LDN key.
Programming a Subattendant Set
The programming for a subattendant set is provided already completed in
the default database (see page 316 for the defaults). If you are starting with
a blank database default, follow the steps below to program the console:
1. Form 01, System Configuration
- Program a Digital Line Card or DNIC module.
2. Form 09, Desktop Device Assignments
- Assign set type to SUB, extension number, COS, COR, and name
(optional) for each bay/slot/circuit.
- Assign a separate COS with subattendant options.
- Set type SUB can only be SUPERSET 4150, SUPERSET 430, or
SUPERSET 4DN.
- Complete the sub-form for assigned keys, types, and options.