Telos Zephyr Xstream Two-Way Radio User Manual


 
USER’S MANUAL
Section 3: GUIDED TOUR of the HARDWARE 53
ParallelInputs07
Allinputsarespeciallytreatedtoaccepteitheravoltage(upto24VDC),oraclosuretoground,
whichmaybeprovidedbyswitches,relays,orlogicoutputs.Theinputsareactivelow.Inother
words,shortingtheinputtogroundcausesittobecometrue(i.e."asserted").
Abuiltin1kΩpullupresistorisprovidedsoTT
Loutputscanbedirectlyinterfaced.Seebelow
forasimplifiedschematicoftheinputcircuitry.
+5 VDC
(30 Volts max)
INPUT
PIN 25
Parallel logic input circuit
t
DEEP TECH NOTE!
The Zephyr Xstream’s “universal” logic input circuit can be used with switch or relay
closures, voltage levels up to 24 Vdc, or logic outputs – either “totem-pole” or open-
collector.
TheinputscanbetransmittedtothefarendZephyrXstreamwhenusingtheLayer3orAAC
codingmode.TheinputscanalsobeusedforlocalcontrolfunctionalitysuchastriggeringDial
Setups(PanicDial).RefertoSection11.5(DetailedMenuReference)forthemenuselections
relatingtothesefunctions
.