USER’S MANUAL
Section 12: System Functions and Remote Control 247
Contact Closures
ForadditionalinformationonconnectingtotheparallelGPIOportseemanualSections3.2
(GuidedTouroftheHardware‐nonmixer)andSection3.4GuidedTouroftheHardwareMX/P
andSection11.6‐11.7(DetailedMenuReference).
ParalleloutputsmaybeaffectedeitherbythecorrespondinginputattheremoteZephyror
Xstream(en
d‐to‐endoperation),orcanbeusedtomonitorfunctionsoftheXstream.See
Section11.6fordetailsonthemenuselectionsaffectingthecontactclosuresfunctionality.
Normally,theclosuresaresimplypassed‐throughfromoneendtotheother.Thefunctionof
eachinputoroutputcanbesetusingth
efrontpanel:
12.2 Remote Control
The Command Line Interface
Thecommandlineinterfacecanbeaccessedintwoways:ViatheRS‐232serialportorbyusing
TelnettoaccesstheunitoverIPthroughtheserialport.
RS‐232Port
TheRS‐232serialportcanbeusedforcomputercontrolofthesystem.Fullstatusandcontr
ol
areavailableviathisport,includingISDNdialing,storageofset‐ups,etc.
ThecommunicationprotocolissimpleASCIItext,soitmaybeusedeasilywithanycomputer
andterminalemulationsoftware.Someareusingapalmtopcomputerwithmacrostocontrol
theirXstreamsinthefield
Some“terminalem
ulation”softwarepossibilitiesare:
• ForthePC:Crosstalk,Procomm,MSWindowsbuilt‐inHyperTerminal,etc.
• FortheMacintosh:Z‐Term,WhiteKnight,etc.
TheZephyrXstreammaybeconnectedlocallytoapersonalcomputer,ortoamodemfor
controlfromaremotesite.Therewillbediffere
ncesintherequiredcabling,asdescribedinthe
Section3.TheZephyrXstreamserialportisconfiguredasDCE(DataTerminalEquipment),
whichmeansitlooksliketheconnectiononamodem,ratherthanonacomputer.
• Withlocalcomputeroperation,astandard(non‐null)cableisuse
d.
• Withamodemconnection,aspecial"nullmodem"cableisrequired.For
moreinformationonthecorrectcableseeSection4.
Accessingthecommandlineusingtheserial port
Note,thissamecommandlanguageisavailableusingTelnettoaccesstheZephyrXstream.
FirstconnecttheXstreamtoacomp
uter’sserialport.SincetheXstreamhasaDCEinterfaceyou
willneedtouseastraightthroughcable.