Telos Zephyr Xstream Two-Way Radio User Manual


 
USER’S MANUAL
Section 11: THE WORKS – Detailed Menu Reference 221
TEL – Screen 3:
Telco:
ThisisyourISDNprotocol.ThismustbesetcorrectlyfortheXstreamtomakeorreceivecalls.
SelectthecorrectvalueforyourISDNBRIcircuit.Section7(ISDNBasics)hasadditional
backgroundinformationonISDN.
ThecorrectsettingwillbedeterminedbythetypeofCentralOfficeswitchprovidingyourIS
DN
service.Notethatsomeswitchesoffermorethanoneprotocol.Seebelowforatableshowing
thecorrectsettingsforcommonlyusedswitches.
TELCO SWITCH BRI LINE
PROTOCOL
CORRECT TELCO
SETTING
NOTES:
AT&T/Lucent 5ESS AT&T Custom Point
to Point
AT&T Cust. (PTP) No SPIDs. One phone
number accesses both
channels
AT&T/Lucent 5ESS National ISDN-1
National ISDN-2
Natl. I-1 SPIDs required
DNs required
NORTEL DMS-100 Custom Functional DMS Cust. SPIDs required
DNs required
NORTEL DMS-100 National ISDN-1
National ISDN-2
Natl. I-1 SPIDs required
DNs required
JAPAN NTT Ins 64 Ins 64 No SPIDs
MSNs may be used
(optional)
EUROPE & Others
(Various switches)
ETS 300 ETS300 NO SPIDs
Used in most countries
including Europe,
Australia, South Africa,
and most of South
America.
Multiple terminals
frequently share the S
interface.
MSNs may be used
(optional)