Appendix 9 – Modular Cable Guide 340
NotethatTIA/EIA‐568‐AT568Biselectricallyequivalent,howevertheGreenandOrangepairs
arereversedasfollows:
PIN COLOR
1 White/Orange
2 Orange
3 White/Green
4 Blue
5 White/Blue
6 Green
7 White/Brown
8 Brown
TIA/EIA568AT568Bcolorcodes.NotethatthisiselectricallyIdentical
toTIA/EIA568AT568A,howeverthegreenandorangepairsare
switched.
h
Hot Tip!
While TIA/EIA- 568- A T568A and TIA/EIA- 568- A T568B are electrically equivalent,
care must be taken that both ends of a given cable utilize the same system. For that
reason, we strongly recommend choosing one of the two standards and using It
throughout your facility.
Standard10BaseTEthernetCablePinout
TraditionallyEthernet10Base‐TcablesusetheGreenandOrangepairoftheTIA/EIA‐568‐A
T568AorTIA/EIA‐568‐AT568Bwiringconfiguration.Thefull4‐pairTIA/EIA‐568‐AT568Aor
T568Bconfigurationswillworkjustfine(seeabove).
Crossover10BaseTEthernetCablePinout
Whenconnectinga10Base‐Tdevice(suchasacomputerortheZephyrXstream)toahub,a
“straightthrough”cableisused(seeabove).Notethatthisimpliesthatfunctionalityofthejacks
onthehubaredifferentfromthoseonthecomputer,sincethe“outpu
t”ofonemust
correspondtothe“input”oftheother.Therefore,thestandardcablewillnotworkifyouwish
toconnectacomputerdirectlytotheZephyrXstream.Thiscanbeaccomplishedwiththespecial
cablebelow.
10Base-T Crossover Cable
PIN COLOR PIN
1 White/ Green 3
2 Green 6
3 White/Orange 1
4 Blue Not Used
5 White/Blue Not Used
6 Orange 2
7 White/Brown Not Used