Telos Zephyr Xstream Two-Way Radio User Manual


 
USER’S MANUAL
Section 3: GUIDED TOUR of the HARDWARE 52
ParallelOutputs07
Outputsareopencollectortogroundandcansinkupto125mAofcurrenteach(actually,any
outputcansinkupto400mA,howeverthemaximumcombinedcurrentshouldbekeptbelow
1000mA).
w
IMPORTANT!
Outputs on Zephyr Xstream motherboards prior to Rev G (1401-0000--007) cannot be used
with external pull ups higher than 5 volts.
If this ability is required, please contact Telos customer support.
Thesewillincludea10kohm5voltpullupresistortoallowdirectinterfacewith5voltlogic
inputsonotherequipment.Ifyourotherequipmentusesavoltagegreaterthan5volts,youwill
needandexternalpullupresistor,unlessitisbuiltintothatequipment'sinputs.An
appropriatev
alueisintherangeif2.2K
Ωto10KΩ.Operationwithlogicinputsrequiringa
voltagelessthan5voltsisnotpossible.
IfusedwitharelayorLED,thentieyourexternalpowersourcegroundtopin25(orusethe5
VDCpowersuppliedonpin1)andrunthispowersourcethroughyourdevice,witharesistorin
seriestolimi
tmaximumcurrenttolessthan125mA.
Theoutputscanalsobeusedformonitoringthestatusoftheunit.Thisfunctionalitycanbeset
byseveralmenuselectionsinSYSTEMmenu.RefertoSection11.5(DetailedMenuReference)
forthemenuselectionsrelatingtotheseoutputs.
+5 VDC
(400 mA max)
OUTPUT
Equivalent schematic for the Parallel Outputs.
An external pull up resistor can be used if voltages greater than 5 volts are used. Alternatively, a
voltage source (such as the 5 volts on pin 1) can be driven through an external device (such as a
relay or LED) into the input.