Panasonic KX-TVP200 Answering Machine User Manual


 
4.3 CONNECTING THE VPS WITH THE PANASONIC KX-TD816, KX-TD1232 AND KX-TD612
Installation Manual 91
4.3.2 KX-TD1232 Software Verification and Programming for
DPT Integration via the Operating and Maintenance
Tool
Follow these steps after communication between the KX-TD1232 and the programming
software has been established. Refer to the Operating and Maintenance manual for
connection information.
A. Programming based on DOS terminal
1.
Check the software version.
a)
Go to the Main Menu. Press the ALT key and the letter [V] at the same time.
b)
Verify the Operating and Maintenance version being used.
Note
If you have an older version of the maintenance tool but have the correct ROM
version in the system, you may still program the KX-TD1232 but you must
program using the Manager's Extension.
c)
Verify the ROM version of the KX-TD1232.
Example: P111GYMMDD
B
If the software version of the PBX is old, you may not be able to utilise some of
the features available only with DPT Integration. For more information, consult
your dealer.
In the example above, the underlined digits represent the software production date code
(year, month, day).
2.
Go to the Main Menu. Choose "System Data Programming" (BATCH [1] or
INTERACTIVE [2]).
Main Menu
Sample display: DB data (PC): Empty
Version:3.03X
1. System Data Programming (BATCH)
2. System Data Programming (INTERACTIVE)
3. Disk File Management
4. DSHS Management
5. DSHS Connect/Disconnect
6. Quit
Select the number : [ ]