Panasonic KX-TVP200 Answering Machine User Manual


 
B7 SYSTEM ADMINISTRATION—HARDWARE SETTINGS
268 Installation Manual
To program the following 10 Parameters in the next table, use the Special Commands and Dial
Codes listed below. You can set up to 12 digits for each parameter.
D: Disconnecting
F: Flash (Recall)
R: Ringback Tone Detection
S: Silence Detection
T: Dial Tone Detection
W: Wait for 1 s
X: Extension dialling
A: Answer
1-9, 0, , #: Dial Codes
Table B-41
Parameter Value Range
(Default)
Description/Function
Integration
Mode
1. None
2. Inband
3. DPT
(None)
Specifies the method of integrating the VPS with the
PBX.
1. NoneBoth PBX and VPS work independently,
without accessing information concerning the status
of the other.
2. InbandThe PBX sends touchtone codes to the
VPS to indicate the state of the call (busy, answered,
disconnect, etc.). Inband Integration improves the
VPS performance because call state recognition is
faster than with standard call progress tone
detection. The PBX code for each call state must be
set in the Inband Signaling Parameters. If PBX type
is set to a KX-T series telephone system, the Inband
Signaling Parameters will automatically default to
the proper codes. This is available with any of the
following Panasonic KX-T series telephone systems:
TA series, T96, T336, TD816, TD1232, TD612 and
TD500.
3. DPTThe VPS communicates with the PBX via the
DPT interface. This is available with any of the
following Panasonic KX-TD series telephone
systems: TD816, TD1232, TD612 and TD500.
Table B-42
Parameter Value Range
(Default)
Description/Function
Operator
Transfer
Sequence
(FX)
The VPS performs this sequence when transferring calls
to the operators extension.
Extension
Transfer
Sequence
(FX)
The VPS performs this sequence when transferring calls
to any extension except the operators.