COS Nos. 63 & 64 (for Managers)
Only the parameters listed below can be assigned for COS numbers 63 and 64. COS number
64 cannot assign the parameters relating to the Message Waiting Notification and the Remote
Call Forward to CO features.
To access the proper menu for Class of Service Numbers 63 & 64 for Managers,
follow the menu path as shown:
System Administration Top Menu-1-2-COS No.(63-64)
Table B-8
Parameter Value Range
(Default)
Description/Function
New Message
Retention Time
1-30 days
(30)
Defines the number of days that an unplayed message can
remain in the mailbox. The storage period begins the day
after massage reception.
Saved
Message
Retention Time
1-30 days
0: Unlimited
(30)
Defines the number of days a played saved message will
remain in the mailbox. The timing is "refreshed" whenever
the message is played back. If "0: Unlimited" is selected,
saved messages will remain in the mailbox until erased by
the mailbox owner.
Message
Length
1-6 min
0: Unlimited
(6)
Defines the maximum message length.
If set to "0: Unlimited", a manager can record two-way
conversations of unlimited length into his or another
persons mailbox (Two-Way Recording or Two-Way
Transfer). The maximum recording time for other messages
will automatically be set to 6 min.
Mailbox
Capacity
Maximum
Messages
5-100 msgs
(100)
Specifies the maximum number of (both new and saved)
messages that can be stored in a mailbox.
Mailbox
Capacity
Maximum
Message Time
5-100 min
0: Unlimited
(100)
Specifies the total number of available minutes for storing
(both new and saved) messages in each mailbox.
Message
Retrieval Order
1. LIFO
2. FIFO
(LIFO)
Specifies the order in which messages will be retrieved
(played back for listening).