Panasonic KX-TVP200 Answering Machine User Manual


 
4.3 CONNECTING THE VPS WITH THE PANASONIC KX-TD816, KX-TD1232 AND KX-TD612
Installation Manual 89
10.
Change the PBX type in the VPS programming menu in the following sequence.
System prompts [>] are displayed on the screen. Press ENTER.
Screen output:
Go to the PBX type selection menu,
By selecting your terminal type [1] or [2] and press ENTER,
Select [1] and press ENTER
Select [6] and press ENTER
Select [3] and press ENTER
Select [1] and press ENTER
Screen output:
Select [2] (and press ENTER)
Select [7] (and press ENTER)
Escape the programming menu by entering Backslash Key until System prompt
[>] comes to be visible.
Check the LED on the VPS unit. If the light is on, the DPT connection between VPS
and PBX is established.
If the LED is flashing, the DPT connection cannot be established.
Possible causes of the message: "DPT Interface Connection is not Established"
Table 4-3
Cause Remedy
The PBX is not a KX-TD series system. Since
the VPS is configured to communicate with the
KX-TD1232, this message will always appear
when connecting to another type of PBX.
Connect a KX-TD series PBX
and set the PBX type by using
Quick Setup (see
CUSTOMISING THE
SYSTEM).
The cabling between the PBX extension ports
and the VPS is not 4-wire or is improperly
connected.
Confirm the cabling is
connected as described in
INSTALLATION.
The PBX is a KX-TD series but does not have
the proper level of software required to support
DPT Integration.
Consult your dealer
or use Inband Integration under
hardware settings.
The PBX is not programmed properly to support
DPT Integration.
Do required integration
programming as described in
this chapter.
Please Select Your Terminal Type.
1. ASCII TERMINAL
2. VT100
Please Enter the Number := ______
Programm - Hardware Setting - PBX Interface Parameters - Dialing Parameters Menu
PBX Type [Other]
1. Other Manufacturers 2. KXT series
Enter the Model Number
1. T308 2. T616 3. T1232/TA series 4. T96 5. T336
6. TD816 7. TD1232/612 8. TD500 9. Reserved