Panasonic KX-TVP200 Answering Machine User Manual


 
7.2 UTILITY COMMANDS
Installation Manual 153
7.2.7 Saving the System Data to the Backup Device (SAVE)
All system programming data and voice prompts (8 functional areas) can be saved in separate
data files. To save this data, connect a data terminal to the RS-232C port of the VPS. Save the
files individually. Execute the SAVE command for each data file. It will require several minutes
DISK ERROR: System Data Error!! Error Loading of administrator data from system
HDD.
SYSTEM ERROR: 1 Administrator data error.
SYSTEM ERROR: 2 Error loading of report data.
SYSTEM ERROR: 3 Clock error.
SYSTEM ERROR: 4 Mailbox data error.
SYSTEM ERROR: 5 Message data error (1).
SYSTEM ERROR: 6 Message data error (2).
SYSTEM ERROR: 7 Error loading of control data.
SYSTEM ERROR: 8 Error loading of voice prompt data.
SYSTEM ERROR: 9 Error loading of MWL control data.
SYSTEM ERROR: 10 Error loading of disk identify data.
SYSTEM ERROR: 11 Error writing of VBI chain data.
SYSTEM ERROR: 12 Error writing of BLK chain data.
SYSTEM ERROR: 13 Error loading of user prompt modify data.
SYSTEM ERROR: 14 Error loading of Class of Service data.
No CO lines are active!! No Port cards present.
COs are all disabled!! All Ports are malfunctioning.
DPT Interface Connection is not
Established.
Ports are malfunctioning for DPT Integration
because telephone lines are disconnected or
Integration with PBX is not set to DPT integration
mode.
Table 7-4 Error and Warning Indications During System Operation
Indication Meaning
DISK STORAGE SPACE IS NOW
EXCEEDING
80%...
80 % or more of the HDD voice storage
area is used.
ASCII TERMINAL program Load Error Error loading of ASCII terminal control
programme.
VT100 program Load Error Error loading of VT100 control
programme.
Table 7-3 Error Indications at System Startup