Other Parameters-Message Waiting Notification
Controls the handling of message waiting notification calls.
To access the proper menu for Message Waiting Notification Parameter, follow the
menu path as shown:
System Administration Top Menu-1-5-7-3
Table B-30
Parameter Value Range
(Default)
Description/Function
Outgoing Call
Ports
Port No.
(1-12)
Specifies the port numbers used for the Message Waiting
Notification Device feature. The VPS makes outgoing
calls using the port specified in this parameter. At least 1
port must be specified.
Message
Waiting Lamp
Ports
Port No.
(1-12)
Specifies the port numbers used for the Message Waiting
Notification Lamp feature.
The VPS turns on the Message Waiting Lamp of the
extension using the port specified in this parameter. At
least 1 port must be specified.
Message
Waiting Lamp
for Every
Message
1. No
2. Yes
(Yes)
If set to "Yes", the VPS will turn on the Message Waiting
Lamp of the extension each time a new message is
recorded in the mailbox. This will occur even if the
Message Waiting Lamp was not turned off from a
previous message. This setting is useful when the first
attempt is unsuccessful.
If set to "No", the VPS will turn on the Message Waiting
Lamp for the first message only. The VPS will not turn on
the lamp for subsequent messages until the subscriber
has accessed the VPS to retrieve the messages stored
there.
Max. Digits for
Callback No.
1-48 digits
(20)
Specifies the maximum number of digits the caller can
enter as a callback number. This number will display on
beepers (pagers) if the "Beeper Callback No. Entry
Mode" is enabled.
Callback No.
Entry Interdigit
Time-Out
1-10 s
(5)
Sets the maximum allowable time between each digit on
Beeper Callback No. Entry. If the caller does not enter
any digits within the specified time, the VPS will not
accept entry of any additional digits.