DCS MMC PROGRAMS
COMBINED PROGRAMMING MANUAL NOVEMBER 2001
MMC 200 (Page 1 of 1)
MMC: 200 OPEN CUSTOMER
PROGRAMMING
DCS
33
CI
33
CII
33
816
33
408i
33
408
33
Used to open (enable) or close (disable) customer-level programming by the system administra-
tor. If programming is not opened and an attempt is made to access a customer-level MMC, the
error message [NOT PERMIT] will be displayed. A four-digit passcode is required to enable cus-
tomer programming (which can be changed in MMC 201, if required). Each digit can be 09.
When opened, this MMC allows access to all MMCs specified by the system installer in MMC
802, Customer Access MMC Number.
PROGRAM KEYS
UP & DOWN Select open or closed
KEYPAD Used to enter passcode
SPEAKER Save data and advance to next MMC
TRSF Exit Programming
ACTION DISPLAY
1. Press TRSF 200
Display shows
ENABLE CUS.PROG.
PASSCODE:_
2. Enter passcode
ENABLE CUS.PROG.
PASSCODE: ∗∗∗∗
Correct code shows
ENABLE CUS.PROG.
DISABLE
Incorrect code shows
ENABLE CUS.PROG.
PASSWORD ERROR
3. Dial 1 for ENABLE or 0 for DISABLE
OR
Press UP or DOWN arrow key to select ENABLE or
DISABLE and press RIGHT soft key
ENABLE CUS.PROG.
ENABLE
4. Press SPEAKER to advance to MMC entry level and
press UP or DOWN key to select MMC (e.g. 212)
OR
2
12:ALARM RING
SELECT PROG. ID
Enter MMC number and press RIGHT soft
key to enter MMC
5. Press TRSF key to exit
Default Data: DISABLE (closed)
Passcode=1234
Related Items: MMC 201 Change Customer Passcode
MMC 501 System-Wide Timers
MMC 802 Customer Access MMC Number