AT&T 1987 AT&T Telephone User Manual


 
trunk CPs (except Tie Trunk CPs) can be connected to a three-way splitter cable (OR6016)
that concentrates the CP interfaces into one 25-pair cable. Up to two Tie Trunk CPs can be
connected to a two-way splitter cable (OR6015) that concentrates the CP interfaces into one
25-pair cable. Each splitter cable connects to an interface block at the TAE.
Cables are cut down or plug into the TAE blocks and plug into the telephone company
provided network interface (RJ21X or RJ2GX). Trunks and tie lines are cut down by the
Telco at the interface.
700A or 157B Blocks are usually used for the TAE connections (furnished by the installer).
700A NETWORK
INTERFACE BLOCKS
(11O-TYPE OR
66-TYPE)
DIGITAL SWITCH
CO NETWORK INTERFACE
FACILITIES
(LOOP AND GRD. START TRUNKS,
OPS, DID TRUNKS)
CO TRUNK
RJ21X
FACILITIES
PORT CP(S)
CO TRUNK
FACILITIES
RJ21X
PORT CP(S)
CENTRAL
OFFICE
ANALOG
LINE CP
(TN-742)
TIE TRUNK
RJ2GX
FACILITIES
TIE LINE
PORT CP(S)
LEGEND:
A
- SINGLE-ENDED 25-PAIR CONNECTOR CABLE (A25D)*
B - 3 TO 1 SPLITTER CONNECTORIZED CABLE (OR6016) - PEC 2720-06X
c
- 2 TO 1 SPLITTER CONNECTORIZED CABLE (OR6015) - PEC 2720-05X
OPS - OFF-PREMISES STATION
SIP - STATION INTERCONNECT PANEL*
D
- OCTOPUS CABLE (WP90780) - PEC 2720-05P
E - INSIDE WIRE*
*
- FURNISHED BY INSTALLER
Figure 4-18. Trunk Access Equipment (TAE) Connections
4-47