SYSTEM 25
PART OF
CABINET
OCTOPUS
CABLE
ZTN82
———
OR ZTN128
C2
●
CALL
PROCESSOR
———
PART OF
SIP
Z210A
C1
355AF
C3
Z3A4
ADU
C1
ADAPT.
ADAPT.
PART OF
SIP
EQUIPPED WITH A THREE FOOT PLUG-ENDED EIA CORD - PEC 2169-001
EQUIPPEO WITH A 3 FOOT RECEPTACLE ENDED EIA CORD
MODULAR POWER CORD (D6AP-87)
MODULARIZES 2012D TRANSFORMER
POWER ADAPTER
C4
SYSTEM
❘ ❘
Z3A1
C1
ADMINISTRATION
B1
W1
SIP
400B2
❘
❘
TERMINAL
ADU
ADAPT.
ADAPT.
❘
❘
———————
———————
LEGEND :
C7
2012D
248B
TRANS.
ADAPT.
B1 -
TYPICAL-103A CONNECTION BLOCK*
C1
- MODULAR CORD (D8W-87) - PEC 2725-07G
C2 -
OCTOPUS CABLE (WP90780) - PEC 2720-05P
C3 -
EIA CROSS OVER CABLE (M7U-87) - PEC 2724-30C
C4 -
ADU CROSS-OVER CABLE (D8AM-87) - PEC 2724-38X
W1 -
4 PAIR INSIDE WIRING CABLE*
355AF ADAPTER RS-232 RECEPTACLE TO MODULAR JACK - PEC 2750-A25
Z3A1 ADU -
Z3A4 ADU -
C7 -
248B ADAPTER -
400B2 ADAPTER -
PEC 21691
2021D TRANSFORMER -
15-18V AC TRANSFORMER
*
- FURNISHED BY INSTALLER
Figure 2-47. SAT On-Premises Direct Connections (Greater Than 50 Feet From
System Cabinet)
2-230