AT&T DS1/DMi/ISDN-PRI Telephone User Manual


 
ADMINISTRATION OPTIONS AND REQUIREMENTS — GENERIC 2
7-65
Field 20
This display-only field serves to show which cables contain which synchronization
cables.
Procedure 262 Word 1: Additional DMI-MOS/ISDN-PRI Facility Options
Procedure 262 is used to administer the ANN35 and TN767 circuit packs. Figure 7-29, Procedure
262 Word 1: Additional DMI-MOS/ISDN-PRI Facility Options (Generic 2), depicts this procedure.
ENHANCED MODE - PROCEDURE: 262, WORD: 1
ISDN BOARD PARAMETERS
EQUIPMENT LOCATION 13. PRI Interface Identifier:
1.
2.
3.
4.
5.
Module:
Cabinet:
Carrier:
Slot:
Circuit:
PRI PARAMETERS
6.
7.
8.
Interface Type:
Facility Test Code:
Terminal Endpoint Identifier:
PRI AND BRI LAYER 2 PARAMETERS
9.
10.
11.
12.
Timer T203:
Timer T200:
Counter N200:
Counter K:
Connect to CC0 ON-LINE
enter command:
Figure 7-29. Procedure 262 Word 1: Additional DMI-MOS/ISDN-PRI Facility Options (Generic 2)
Fields 1-4
Assigns the circuit pack to an equipment location. These include the module
number, cabinet number, Port carrier number, and slot number.
Field 5
NOTE: Entries for these four fields are the default values from translating a
five in field 14 of procedure 260. These entries should always be correct.
BRI Only
For ISDN-PRI and DMI-MOS applications, the dash (–) is appropriate.