AT&T DS1/DMi/ISDN-PRI Telephone User Manual


 
7-6
ADMINISTRATION OPTIONS AND REQUIREMENTS — SYSTEM 85
Field 4
V1-V4
Translates a particular type of carrier (such as DS1/MFAT, module control, or
TMS) to the equipment location identified by fields 1-3. For DS1/DMI/ISDN-PRI
applications the pertinent encodes are:
4
5
6
7
8
9
TMS 0 control
TMS 0 growth
Module control 0
Module control 1
TMS 1 control
TMS 1 growth
11
DS1/MFAT port carrier
Select a particular encode based on the intended purpose for translating this
procedure, either to assign the SC or to assign a DS1/MFAT carrier.
Fields 5-10
V1-V4
DS1/DMI/ISDN-PRI does not place any additional requirements on translating these
fields.
Field 11
V1-V4
Field encodes and their descriptions are:
0
1
When the carrier (which is identified by fields 1-10) is not equipped with an SC.
When an external synchronization clock is used, do not administer the SC. The
SC software functions are replaced by the hardware/firmware contained within
the external clock.
When the carrier (module control or TMS) is equipped with an SC. The
network synchronization plan should be available, and is required, to determine
how to properly synchronize the switch.
Fields 12-15
V1-V4
Not applicable for DS1/DMI/ISDN-PRI applications. Therefore, a dash (–) is
appropriate.
Procedure 260 Word 1: DS1/DMI/ISDN-PRI Physical Interface
System 85 R2V3 DS1 administration software (procedure 260) contains all the same fields, options,
and considerations as R2V1 and V2. Procedure 260 also provides a new field (14) for defining new
application types for DS1 facilities. The R2V3 systems require the ANN11C, ANN11D, or
ANN11E vintage circuit pack to provide the OPS line option. The ANN11D or ANN11E is
required to provide the DMI-BOS option.