AT&T DS1/DMi/ISDN-PRI Telephone User Manual


 
ADMINISTRATION OPTIONS AND REQUIREMENTS — SYSTEM 85
7-7
System 85 R2V1 and V2 only provide trunks. However, R2V3 and V4 provide trunks, analog OPS
lines, and DMI-BOS trunks. System 85 R2V4 (and later versions) provides DMI-MOS trunks; refer
to table 7-1,
DS1 Administration
Channel Versus Line Assignments.
Depending on the application type (encode) translated, there may be additional administration, slot,
and port grouping restrictions.
Service or Facility Options
Procedure 260 is used to administer the DS1/DMI/ISDN-PRI Interfaces (ANN11B, ANN11C,
ANN11D, ANN11E, or ANN35). Figure 7-4, Procedure 260 Word 1: System Configuration, Circuit
Pack Assignments (System 85 R2V4), shows procedure 260, word 1.
ENHANCED MODE - PROCEDURE: 260, WORD: 1
DS1/ISDN AND RG CIRCUIT PACK ASSIGNMENTS
EQUIPMENT LOCATION SC
1.
2.
3.
4.
Module:
Cabinet:
Carrier:
Slot:
12.
13.
Equipment Type:
SC Reference:
14.
15.
Application:
Bit Inversion:
SIGNALING
16.
17.
Link Type:
SA/FX:
6.
7.
8.
9.
Framing:
PCS/CCS:
24C/RBS
ZCS/B8ZCS:
DISPLAY ONLY:
18.
SC Information:
10.
11.
Slip Enable:
External Loop:
Connected to CC0 ON-LINE
enter command:
Figure 7-4. Procedure 260 Word 1: System Configuration, Circuit Pack Assignments (System 85
R2V4)
Fields 1-4
V1-V4
Assigns the circuit pack to an equipment location. These assignments include the
module number (0 through 30), cabinet number (0 through 7), DS1/MFAT carrier
number (0 through 3), and slot number (5 or 18) for line plus trunk operation; or
slot numbers (0, 5, 13, or 18) for line-only operation.
System 85 R2V4 permits only trunk mode operation (that is, only slot numbers 5 or
18 can be assigned).