SELECT CYCLIC SYMMETRY M ODES
18.6
*
SELECT CYCLIC SYMMETRY MODES: Specify the cyclic symmetr y modes in an
eigenvalue analysis of a cyclic symmetric structure.
This option is used to specify which cyclic sy mmetry modes should be used in an eigenvalue analysis.
Product: ABAQUS/Standard
Type: History data
Level: Step
References:
•
“Analysis of m odels that exhibit cyclic symmetry,” Section 10.3.3 of the ABAQUS Analysis User’s
Manual
• *
CYCLIC SYMMETRY MODEL
• *
TIE
Optional parameters:
EVEN
Include this parameter to request the even cyclic symmetry modes only. If this parameter is omitted,
all cyclic symmetry modes will be used within the NMIN , NMAX range.
NMIN
Set this parameter equal to the lowest cyclic symm etry mode number. The default value is 0.
NMAX
Set this param eter equal to the highest cyclic sym metry m ode number. The default value is the
highest number that is feasible for the number of sectors given in the
*
CYCLIC SYMMETRY
MODEL option.
There are no data lines associated with this option.
18.6–1