3D Connexion Version 6.6 Two-Way Radio User Manual


 
*
INSTANCE
9.19
*
INSTANCE: Begin an instance definition.
This option is used to instance a part within an assembly. It must be used in conjunction with the
*
ASSEMBLY
and
*
END INSTANCE options. If the instance is not imported from a previous analysis, the
*
INSTANCE
option must be used in conjunction with the
*
PART option. When importing a part instance from a previous
analysis, the
*
INSTANCE option must be used in conjunction with the
*
IMPORT option.
Products: ABAQUS/Standard ABAQUS/Explicit
Type: Model data
Level: Assembly
References:
“Defining an assembly,” Section 2.9.1 of the ABAQUS Analysis User’s Manual
“Transferring results between ABAQUS analyses: overview,” Section 9.2.1 of the ABAQUS Analysis
User’s Manual
*
END INSTANCE
*
IMPORT
Required parameters if the instance is not imported from a previous analysis:
NAME
Set this parameter equal to a label that will be used to refer to the instance.
PART
Set this parameter equal to the nam e of the part being instanced.
Required parameter if the instance is to be imported from a previous analysis:
INSTANCE
Set this parameter equal to the name of the instance to be imported from the previous analysis.
Optional import parameter:
LIBRARY
Set this parameter equal to the na me of the previous ana lysis from which the instance should
be im ported. The previous analysis output database (.odb) file should reside in the current
(working) directory. If the LIBRARY parameter is omitted, the job name of the previous analysis
must be specified on the command line using the oldjob parameter (see “Execution pro cedure
for ABAQUS/Standard and ABAQUS/Explicit,” Section 3.2.2 of the ABAQUS Analysis User’s
Manual). If both methods are used, the command line specification will take precedence over the
LIBRARY param eter.
9.19–1
ABAQUS Version 6.1 Module:
ID: