MODEL CHANGE
13.15
*
MODEL CHANGE: Remove or reactivate elements and contact pairs.
This option is used to remove or reactivate elements or contact pairs during an analysis.
Product: ABAQUS/Standard
Type: History data
Level: Step
References:
“Element and contact pair removal and reactivation,” Section 11.2.1 of the ABAQUS Analysis User’s
Manual
“Removing/reactivating ABAQUS/Standard contact pairs,” Section 29.2.6 of the ABAQ US Analysis
User’s Manual
Required, mutually exclusive parameters:
ACTIVATE
Include this parameter in any step during an analysis to indicate that elements or contact pairs may
need to be removed or added during a subseque nt restart analysis.
ADD
Include this parameter to indicate that the elements or contact pairs involved are being reactivated
during the step.
Set ADD=STRAIN FREE (or include the ADD parameter without a value) to specify strain-
free reactivation for stress/displacement elements or to reactivate other elements or contact pairs.
Set ADD=WITH STRAIN to specify that stress/displacement elem ents are reactivated with
strain. This option is not relevant for contact pairs.
REMOVE
Include this parameter to indicate that the elements or contact pairs involved are being removed
during the step.
Optional parameter:
TYPE
This parameter can be used only with the parameters ADD or REMOVE.
Set TYPE=ELEMENT (default) to rem ove or reactivate elements. Set TYPE=CONTACT
PAIR to rem ove or reactivate contact pairs.
13.15–1
ABAQUS Version 6.1 Module:
ID:
Printed on: