3D Connexion Version 6.6 Two-Way Radio User Manual


 
*
INTEGRATED OUTPUT
9.20
*
INTEGRATED OUTPUT: Specify variables integrated over a surface to be written to
the output database .
This option is used to write integrated quantities over a surface, such as the total force transmitted across a
surface, to the output database. It must be used in conjunction with the
*
OUTPUT, HISTORY option.
Product: ABAQUS/Explicit
Type: History data
Level: Step
References:
“Output to the output database,” Section 4.1.3 of the ABAQUS Analysis User’s Manual
“Integrated output section definition,” Sec tion 2.5.1 of the ABAQUS Analysis User’s Manual
*
OUTPUT
*
SURFACE
*
INTEGRATED OUTPUT SECTION
Required, mutually exclusive parameters:
SECTION
Set this parameter equal to the name of the
*
INTEGRATED OUTPUT SECTION (see “Integrated
output section definition,” Section 2.5.1 of the ABAQUS Analysis User’s Manual) over which this
output request is being made.
SURFACE
Set this parameter equal to the name of the surface (see “Defining elem ent-based surfaces,”
Section 2.3.2 of the ABAQUS Analysis User’s Manual) over which this output request is being
made.
Optional parameter:
VARIABLE
Set VARIABLE=ALL to indicate that all integr ated output variables applicable to this procedure
should be written to the output database.
Set VARIABLE=PRESELECT to indicate that the default integrated output variables for the
current procedure type should be written to the output database. Additional output variables can be
requestedonthedatalines.
If thi s parameter is omitted, the int egrated output variables for output must be specified on the
data line.
9.20–1
ABAQUS Version 6.1 Module:
ID: