8.14 Background Music (BGM) Configuration.
Configure the PEKU to support a BGM source in
accordance with the following steps:
1) Remove the PCB from its protective pack-
aging.
2) Cut the W5 (BGM) jumper wire on the PEKU
PCB.
3) Refer to Peripherals Installation, Section 100-
816-207, for installation procedures for BGM
connection.
8.15 External Amplifier Configuration. The
PEKU does not have to be configured to support an
external amplifier. However, the system must be
programmed for one; see Paragraph 8.40. See
Peripherals Installation, Section 100-816-207, for
external amplifier installation instructions.
8.20 PEKU Installation Procedure
8.21 Install the PEKU in accordance with the fol-
lowing steps:
1) Remove the PCB from its protective pack-
aging.
TABLE 5-B
PEKU CONTROLS AND INTERFACE CONNECTORS
CONTROL/INDICATOR/
CONNECTOR (Figure 5-13)
TYPE OF COMPONENT DESCRIPTION
Off-hook Call
Announce P10
DSS/EKT DSS Console/
Electronic Telephone
SW1 Switch
Two-position slide switch Configures PEKU for operation with either
an HDSS console or electronic
telephones.
10-pin connector Interface connector for optional Off-hook
Call Announce subassembly
connector (used in conjunction with P20,
P40, P50, and P60).
Off-hook Call
Announce P20
10-pin connector Interface connector for optional Off-hook
Call Announce subassembly
connector (used in conjunction with P10,
P40, P50, and P60).
Off-hook Call
Announce P40
10-pin connector Interface connector for optional Off-hook
Call Announce subassembly
connector (used in conjunction with P10,
P20, P50, and P60).
Off-hook Call
Announce P50
10-pin connector Interface connector for optional Off-hook
Call Announce subassembly
connector (used in conjunction with P10,
P20, P40, and P60).
Off-hook Call
Announce P60
10-pin connector Interface connector for optional Off-hook
Call Announce subassembly
connector (used in conjunction with P10,
P20, P40, and P50).
BGM source connection
W5 Jumper Wire
When cut, configures PEKU for BGM
source connection.
White jumper wire