REMOTE ADMINISTRATION AND MAINTENANCE PROCEDURES
SECTION 100-816-600
MARCH 1993
-23-
TABLE RM-L
PROGRAM 00
SOFTWARE CHECK/REMOTE MAINTENANCE—SECURITY CODE
ACTIONSTEP DISPLAY/PRINTOUT
1 >MODE PROG
P
Enter Program Mode
At the >MODE prompt, enter P R O G CR.
2 P 00
P00
Enter Program Number 00
Press CR.
3 P00 0 Version = PSSA
P00
To Check Software Version
. System will display the system's software
version.
Press CR.
4 P00 1 0000
P00
To Change Level 1 Security Code
5 P00 2 0000
P00
To Change Level 2 Security Code
. The system will display the present
level 1, four-digit code. Refer to the System Record Sheet
and change if required. Press CR.
6 To Exit This Program P00 ##
P
. The system will display the present
level 2, four-digit code. Refer to the System Record Sheet
and change if required. Press CR.
Press # # CR.
Enter Action Code 0
Enter Action Code 1
Enter Action Code 2
•
Software version
Version = QMA
or
For DK16, PSSA. For DK8, QMA