REMOTE ADMINISTRATION AND MAINTENANCE PROCEDURES
SECTION 100-816-600
MARCH 1993
-48-
TABLE RM-AU
PROGRAM 46-10 ~ 40
TOLL RESTRICTION CLASS PARAMETERS
ACTIONSTEP DISPLAY/PRINTOUT
1
>MODE PROG
P
Enter Program Mode
At the >MODE prompt, enter P R O G CR.
2 P 46
P46
Enter Program Number 46
3 P46 10Refer to the System Record Sheet and enter the Toll Restriction
class number (1 ~ 4). Then enter the number 0.
Example: Class 1, enter 1 0.
6 To Exit Program/Store Data
Press CR.
4 Refer to the System Record Sheet and enter the required
button/LED number.
Example: Button number 11, enter 1 1. The system will display
the status of the button/LED.
P46 10 11 TABLE 1N
A)
B)
To store data, press CR.
To exit this program, press # # CR.
5 Refer to the System Record Sheet and change if required (Y or N).
To access next button number, press SPACE.
P46 10 11 TABLE1 N Y
12 TABLE2 N
P46 10 11 TABLE1 N Y
P46 ##
P