Toshiba DK 16 Telephone User Manual


 
8-17
INSTALLATION-WIRING DIAGRAMS
SECTION 100-816-208
MARCH 1993
FIGURE 8-13
DK16 MDF WIRING/ELECTRONIC TELEPHONE TO PEKU
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
W-BL
BL-W
W-O
O-W
W-GN
GN-W
W-BR
BR-W
W-S
S-W
R-BL
BL-R
R-O
O-R
R-GN
GN-R
R-BR
BR-R
R-S
S-R
BK-BL
BL-BK
BK-O
O-BK
BK-GN
GN-BK
BK-BR
BR-BK
BK-S
S-BK
Y-BL
BL-Y
Y-O
O-Y
Y-GN
GN-Y
Y-BR
BR-Y
Y-S
S-Y
V-BL
BL-V
V-O
O-V
V-GN
GN-V
V-BR
BR-V
V-S
S-V
26
1
27
2
28
3
29
4
30
5
31
6
32
7
33
8
34
9
35
10
36
11
37
12
38
13
39
14
40
15
41
16
42
17
43
18
44
19
45
20
46
21
47
22
48
23
49
24
50
25
BRIDGING
CLIPS
TO PEKU W/FEMALE
CONNECTOR
25-PAIR CABLE W/MALE AMP CONNECTOR
66M150 SPLIT BLOCK
CIRCUIT 2
CIRCUIT 3
CIRCUIT 4
CIRCUIT 5
CIRCUIT 6
CIRCUIT 7
CIRCUIT 8
NOT USED
CIRCUIT 2
CIRCUIT 3
CIRCUIT 4
CIRCUIT 5
CIRCUIT 6
CIRCUIT 7
CIRCUIT 8
GN
654321
Y
BL
R
BK
W
123456
OCA T1 (OT)
OCA R1 (OR)
VOICE T1 (VT)
VOICE R1 (VR)
DATA T1 (DT)
DATA R1 (DR)
JACKETED TWISTED PAIRS
24 AWG
MODULAR
CORD
STATION
ONLY IF ELECTRONIC TELEPHONE
RECEIVES "OFF-HOOK" CALLS
To receive OCA, the 6500-series electronic telephone
must have HVSU2 subassembly or combined
HVSU/HVSI subassemblies installed.
Program 31, button/LED 03 must be “on” for
electronic telephone to receive OCA.
1.
2.
3.
4.
NOTES:
ELECTRONIC
TELEPHONE
STATION CABLING
VT
VR
DT
DR
VT
VR
DT
DR
VT
VR
DT
DR
VT
VR
DT
DR
VT
VR
DT
DR
VT
VR
DT
DR
VT
VR
DT
DR
OT
OR
OT
OR
OT
OR
OT
OR
OT
OR
OT
OR
OT
OR
DT
OCAT
OCAR
DR
VR VT
All cable 24 AWG, max 40 ohm loop resistance from
PEKU to electronic telephone (1000 ft).
An HHEU must be installed inside 6500-series
electronic telephones for headset or HESB,