Toshiba DK 16 Telephone User Manual


 
REMOTE ADMINISTRATION AND MAINTENANCE PROCEDURES
SECTION 100-816-600
MARCH 1993
-28-
TABLE RM-S
PROGRAM 12
SYSTEM ASSIGNMENTS – BASIC TIMING
ACTIONSTEP DISPLAY/PRINTOUT
1
>MODE PROG
P
Enter the Program Mode
At the >MODE prompt, enter P R O G CR.
2 P 12
P12
Enter Program Number 12
3 P12 3 1Check the record sheet and enter the program code that is
required.
As an example, feature 3, enter 3.
The present selection will be displayed.
Press CR.
4 P12 3 1 2Refer to the record sheet and change if required.
As an example, change it to 2.
Enter 2.
5 P12 3 1 2
P12 ##
P
To Exit Program/Store Data
A)
B)
C)
To store data, press CR.
Continue returning to Step 3 until all Program 12 data is
entered.
To exit this program, press # # CR.
NOTES:
1. A blank is displayed by "N".
2. Programs 15 and 16 use Type 1 procedure.
TABLE RM-T
PROGRAM 13
DEFINING THE MESSAGE CENTER
ACTIONSTEP DISPLAY/PRINTOUT
1 >MODE PROG
P
Enter the Program Mode
At the >MODE prompt, enter P R O G CR.
2 P 13
P13
Enter Program Number 13
3 P13
P13 1 NN
Enter the number 1. The present port number will be displayed.
Refer to the record sheet and enter the required port number.
Example: Port 00, enter 0 0 CR.
4 P13 1 NN 00
P13
P13 1 NN 00
P13 ##
P
Press # # CR.
5
To Exit this Program
Press CR.