NOTE:
Programs 10-1, 10-2, and 10-3 use Type 1 procedure.
To store data; press CR.
Continue returning to Step 3 until all Program 04
data is entered.
To exit this program, press # # CR.
TABLE RM-O
PROGRAM 04
PORT/STATION NUMBER ASSIGNMENT
ACTIONSTEP DISPLAY/PRINTOUT
1 >MODE PROG
P
Enter the Program Mode
At the >MODE prompt enter P R O G CR.
2 P 04
P04
Enter Program Number 04
Press CR.
3 P04
P04 01
Enter the Logical Port Number
Refer to the System Record Sheet and enter the desired
logical port number.
Example: Port number 01, enter 0 1.
4 P04
P04 01# 11 06
Press # button.
5 P04
P04 01# 11 06
P04 ##
P
To Exit Program/Store Data
System displays present station number. Refer to the
System Record Sheet and enter the desired station number.
Example: Station number 16, enter 1 6.
A)
B)
C)
TABLE RM-P
PROGRAM 05
FLEXIBLE ACCESS CODE NUMBERING
ACTIONSTEP DISPLAY/PRINTOUT
1 >MODE PROGEnter the Program Mode
At the >MODE prompt, enter P R O G CR.
2 P 05
P05
Enter Program Number 05
Press CR.
3 P05 4 4Enter Access Code number that you wish to change (0 ~ 9)
4
5
P05 4 4 6
6
P
To Exit this Program
Example: 4 (if it was not previously changed, the system
will print another 4. If it has been previously changed,
the system will print the number to which it was changed).
Press # # CR.
Change the number if required (one or two digits)
Example: Change to 6, press CR.
Continue returning to Step 3 until all required access