SPECIFICATION
General Description
1. Capacity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Outsides
Max.12
Stations Max.32
2.
Control Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stored Program CPU : 16 bits CPU
Control ROM: 192 KB, Control RAM : 64KB
3.
Switching . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Space Division CMOS Crosspoint Switch
4.
power Supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Primary
AC 12OV 60Hz - >
Secondary
Station Supply Volt : 26V
Circuit Volt : +5V, +12V, -14V, -16V, *7V
Power Failure *Max.6 outsides assigned to stations . . . . ..power
failure transfer
.
l
System operation for several hours by recommended
battery (car type batteries - consisting of two 12
VDC)
5.
Dialing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Outward
Internal
Mode Conversion
6.
Intercom paths . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
7. Outside (CO)-Outside (CO) paths........ 2
8. Connector
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Outsides
(CO)
Station
Paging Output
External Music Input
9. EXT Connection
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cable
10. SMDR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Interface
Station Message
1
Output Equipment
Detail Recording
Detail Recording
Dial Pulse IOPPS, 20PPS
Tone Dial
Dial Pulse IOPPS, 20PPS
Tone Dial
DP-DTMF, DTMF-DP
Modular Jack (RJ-11)
Amphenol Connector
Pin Jack (RCA JACK)
two-conductors Jack (MINIJACK 9/64 inch
diameter)
1 pair wire (Standard Telephone)
2 pair wire
(KX-T1232301 KX-T123220/
KX-T123250/ KX-T61630/ KX-T61620/
KX-T61631/ KX-T61650/ KX-T30825/
KX-T30830/ KX-T30820/ KX-T30850)
3 pair wire (KX-T123235)
RS-232C
Printer, Data Terminal
Data, Time, Ext. Number, CO Number,
Calling Number, Calling Time, Account
Code
Characteristics
1. Station Loop Limit
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
KX-T123230/ KX-T123220/ KX-T123250/ KX-Tl23235/
KX-T61630/ KX-T61620/ KX-T61650/ KX-T61631/ KX-T3d825
KX-T30830/ KX-T30820/ KX-T30850 40 ohms
Standard Telephone 600 ohms including set
Doorp hone 20 ohms
2. Minimum Leak Resistance
. . . . . . . . . . . . . . . . . . . . 15,000 ohms
3. Maximum Number of Station
Instruments per Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1 (KX-T123230, KX-T123220, KX-T123250, KX-T123235, KX-T61630,
KX-T61631, KX-T61620, KX-T61650, KX-T30830, KX-T30820, KX-T30850,
KX-T30825
or Standard telephone) .
4.
Ring Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
70 Vrms at 20 Hz depends on Ringing Load I
5. primary power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
120 Vat, 60 Hz, 1.4 A maximum
6. Central Office Loop Limit..................... 1600 ohms maximum
7. Environmental Requirements...............O-40 C, 10%90%
8. Hookswitch Flash Timing Range.........204-1000 msec
6-8