Description
In the event of a power failure each CO will be
connected to assigned extension.
CO1 will be assigned to extension of jack number 01.
CO2 will be assigned to extension of jack number 02.
CO5 will be assigned to extension of jack number 09.
CO6 will be assigned to extension of jack number 10.
CO9 will be assigned to extension of jack number
17.
CO10 will be assigned to.extension of jack number 18.
Operation
l
If extension of jack number 01,02,09, 10, 17
and 18 is connected with a KX-T123230,
KX-T123235, KX-T61631, KX-T61630 or KX-T30830,
the Power failure switch on the KX-T123230,
KX-T61631, KX-T61630 or KX-T30830 must be set to
the “ON” position during power failure. If dialing
cannot be done, set the Dialing mode switch to other
position (TONE or PULSE).
Conditions
During power failure, all features are lost
except for incoming and outgoing CO calls from
extensions of jack number 01,02,09,10,17 and
18.
If extensions of jack number 01,02,09, 10, 17
and 18 are connected with a KX-T123220,
KX-T123250, KX-T61620, KX-T61650,
KX-T30825, KX-T30820 or KX-T30850,
disconnect the unit and connect a
KX-T123230, KX-T61631, KX-T61630,
KX-T30830 or a standard telephone.
There is no memory loss except for the camp-on,
saved number redial, the last number redial,
Call park and Message Waiting during power
failure, memory is protected by 21 day
rechargeable battery.
Rechargeable battery is good for 5 years.
Automobile type batteries which are customer
supplied is available as a backup power supply
of the KX-T123211 to operate all the features in the
event of power failure. Refer to page 2-34.
For connecting automobile type batteries, use the
Optional Battery Adaptor KX-A26.
Automobile type batteries
[ Consisting of two 12 VDC (24 VDC)]
Description
The elapsed time (from dialing to replacing the
handset) on originating an outside call will be
displayed.
Operation
None
,
Conditions
l
When intercom calls, the duration time of
conversation is not displayed.
0 Refer to “Duration Time Count Start Mode”
on page 3-40.
Description
If a handset of standard telephone remains off
hook
or is disconnected at the other end, a reorder tone
will be heard. When “Calling Party Control (CPC)
Signal” mode is set to “Disable”, the reorder tone
will not be heard. (see page 3-62)
Operation
None
Conditions
l
The party whose handset remains off- hook
will hear a reorder tone to indicate that the
call is disconnected.
Description
Any telephone instrument, whether’(KX-T123230,
KX-T123235, KX-T123220, KX-T123250, KX-T61631,
KX-T61630, KX-T61620, KX-T61650,
KX-T30820, KX-T30825, KX-T30830,
KX-T30850 for exclusive use), standard
rotary phone (10 pps, 2Opps), or standard
touch tone phone, may be used as an
extension of the KX-T123211.
Operation
None
4-51