AT&T R1V2 Telephone User Manual


 
TABLE 16-17 Applicable Options
See WARNING for Table 16-16. Also note that a bullet in a box on this table
indicates that the default value for that action (shown in Table 16-16) is applicable
for this circuit board. No bullet indicates that the option is not applicable.
CIRCUIT BOARD
ACTION
BOARD
TYPE
32
33
34
35*
36 37
38
ZTN76
GS Trunk
ZTN77 LS Trunk
TN753
DID Trunk
TN760
TIE Trunk
TN763
AUX Trunk
TN742
T.T. Station
ZTN78
T.T. Station
ZTN79
ATL Station
TN735
MET Station
ZTN85 S
VC. Ckt.
TN748
Tone Det.
* ACTION 35 (Hybrid Balance) defaults depend on board type. Trunk Ports
are defaulted to 0 (Resistor/Capacitor termination) while Station Ports are
defaulted to 1 (Resistor termination).
16-20 Command Reference