AT&T R1V2 Telephone User Manual


 
TABLE 16-16 Port Options
PORTS, Station/Trunk/Special Port Circuit Board Options
FOR QUALIFIED SYSTEMS TECHNICIANS ONLY*
(See Table 16-17
, “Applicable Options”)
ACTION
DESCRIPTION
DATA
32
Set CO disconnect time (in 20 msec increments)
[0-2540 msec; 500]
33
Set end-to-end signaling tone timing
[0-2540 msec; 60]
(in 20 msec increments)
34
Set end-to-end signaling pause timing
[0-2540 msec; 60]
(in 20 msec increments)
35
Set hybrid balance.
Data is balance type: 1=Resistor;
[1 / 0]
0=Resistor/Capacitor.
Trunk ports default to 0;
station ports default to 1.
36
Set gain; 1 (Gain=3dB) or 0 (Gain=0dB)
[1 /
0]
37
Set E&M signaling type. Data is signaling type 0
[0 - 2]
(Type 1 compatible), 1 (Type V), or 2 (Type I).
38
Set answer supervision delay timing
[0-5100 msec; 300]
* WARNING:
The default values in Tables 16-16 and 16-17 must not be changed without
the support and guidance of Tier III staff.
Command Reference
16-19