2. If the PC is directly connected to the common
equipment, match the data communications
parameters of the software program to those now
programmed at the telephone system.
-OR-
If remote programming is being employed, the data
parameters of the PC must match the modem
connected to it. The modem connected.to the
common equipment must match the data
parameters of it as well.
NOTE: Remember, g-bit data is required for XMODEM
protocol.
If
the common equipment is not now
programmed to provide g-bit data, it
will
have
to be re-programmed from station 10 (see
page
4-7
for details) before data
communications can take place. The baud
rate to match the modem or the PC should be
set at the same time.
Set the data communication parameters as follows:
Press ALT P.
Type 11 the press ENTER. This action selects
a baud rate of 9600 baud.
Type 17 then press ENTER. This action selects
8-bit data.
Type 18 the press ENTER. This action selects
one stop bit.
Type 24 then press ENTER. This action saves
the data parameters.
3. Set the terminal parameters as follows:.
l
Press ALT S.
l
Type 2 then press
ENTER.
l
Type
1
then press ENTER.
l
Use arrow keys to select VDT-100 or similar
emulation then press ENTER.
NOTE:
Settino the terminal emulation for a Wvse-50
or
VT?00
emulation will provide a
whatible
set of default values; however, any emulation
Press ENTER. The COS data, as stored in the
which provides full duplex operation is
computer file, is automatically up-loaded to the
satisfactory.
common equipment.
0
Press
ESC
to finish.
9.
Repeat step 8 except type 3 to down-load currently
stored auto dial and speed dial numbers or type 4
0
Press S then press
ENTER.
This action saves
to up-load them.
the terminal parameters.
lO.Retum to main menu and log off.
IMI 66-083
System Programming ,
Press ESC then press ENTER to end the
terminal parameter set up.
4.
When computer screen displays a prompt for
password, type I
+#
7 4 6 &then press ENTER.
This causes main COS programming menu to be
displayed.
5.
From main menu, type 1 then press ENTER. This
causes system COS programming menu to be
displayed.
6.
From system menu, make all selections necessary
to perform class of service programming then
return to the main menu.
7.
From the main menu, type 4 then press ENTER.
This causes load/save menu to be displayed.
8.
From load/save menu, down-load COS data from
common equipment to computer or up-load COS
data from computer to common equipment,
Down-Load COS Data From Common
Equlpment To Computer
Type 1 then press ENTER.
Press PAGE DOWN.
Type
1
to choose XMODEM protocol.
Type file name for down-loaded COS data to
save into.
Press
ENTER.
The COS data, as programmed
in the common equipment, is automatically
down-loaded to the computer file.
Up-Load COS Data From Computer To Common
Equipment
Type 2 then press
ENTER.
Press
PAGE UP.
Type
1
to choose XMODEM protocol.
Type file name of saved COS data.
4-85