Unit Load Calculation Worksheet
Page B-8
Unit Load Worksheet
If the unit load for slots five and six is less than or equal to 27, power is
sufficient for the carrier.
If the unit load for slots five and six is more than 27, continue to Step 9.
* The MFM has its own wall power unit located at the telephone and therefore is
not added to the unit load calculation.
Up to two DSSs (one DSS per MLX-28D or MLX-20L console) can be powered
from each control unit carrier. For example, a 3-carrier system can have 6
system operator positions, each with one DSS powered from the control unit.
Qty x Unit Load = Total
Equipment
Hybrid/PBX or
Modified Square
Optional Equipment
*
EICON board (CTI link
interface board in Net-
ware server.)
0.0 0.0
Direct Station Selector
0.7 0.9
General Purpose
Adapter 0.8 1.0
Hands-Free Unit 0.8 1.0
Headset Adapter 0.8 1.0
Total Actual Unit Load