Installing Telephones and Adjuncts
Page 3-47
Installing Direct Station Selectors
b. Connect one end of the D6AP cord to the 2-conductor (small)
modular jack on the 400B or 400B2 adapter, and plug the other
end of the D6AP cord into the modular jack of the 406943837 or
406743419 power supply.
!
CAUTION:
Do not plug the D6AP cord into the 8-conductor (large) modular
jack of the 400B or 400B2 adapter. Doing so can cause electrical
damage to the control unit and to the telephone.
c. Insert the plug end of the 400B or 400B2 adapter into the wall
jack.
d. Plug the power supply into a 117-V AC outlet.
!Label the DSS designation cards.
a. Pull the tab at the top of the large plastic cover and rotate the
cover towards you.
b. Remove the cover and the large designation card.
c. Write or type the button assignments on the card. (For DSS1, use
the side that is labeled
00–49;
for DSS2, use the side labeled
50–99.)
The button assignments on the designation card should be by dial
plan extension number, not by logical ID port number.
d. Replace the card and the plastic cover; make sure the coated side
of the cover is facing up.
e. Repeat this step to remove the small plastic cover and to label the
small designation card.
NOTE:
If the MLX telephone attached to the DSS is unplugged from the control
unit and then plugged in again, the display on the telephone may
disappear. Press the Home button to bring back the display.