Lucent Technologies 555-661-140 Telephone User Manual


 
MERLIN LEGEND Communications System Release 6.1
Installation
555-661-140
Issue 1
August 1998
Connecting Data Equipment
Page 6-15
Terminal Adapter Data-Only Stations
!Plug the WP90110-L7 power supply cord into the POWER
receptacle on the terminal adapter.
!Use a 440A4 terminating resistor adapter to connect the terminal
adapter to the control unit.
a. Use a D8W cord to connect the 440A4 terminating resistor
adapter to the LINE jack on the terminal adapter.
b. Use a second D8W cord to connect the other end of the adapter to
the appropriate MLX extension jack. See Form 2b, System
Numbering: Digital Adjuncts for the appropriate module and
extension jack.
!Connect all power cords to an AC outlet not controlled by a wall
switch.